Simplifique os testes de UR – Dicas e recursos de calibração

Relative humidity (RH) moisture testing in concrete requires a properly calibrated in-situ probe to ensure accuracy.

Calibration protects you in case moisture problems come up later, and compliance with ASTM F2170 requires calibration and documentation of it.

Despejar e nivelar uma laje de concreto

Any way you look at it, you want to make sure the in-situ probes you use to measure moisture in concrete are calibrated to requirements.

As a reminder, in-situ probes are placed in holes in the concrete slab, at the right testing depth, to measure the RH within it. In-situ RH testing is widely considered the most reliable way to determine the moisture condition of a concrete slab.

O que a calibração realmente significa?

An in-situ RH probe has two main components: a sleeve and a sensor. The sleeve is installed in the concrete slab. The sensor is placed in the sleeve for performing the actual RH test. The sleeve protects the sensor and helps with proper equilibration for the most relevant RH reading.

The sensor needs to be properly calibrated before use. Calibration ensures that the sensor will provide sufficiently accurate relative humidity measurements to meet the ASTM F2170 standard for relative humidity testing. ASTM F2170 allows more than one way to check calibration, including using a saturated salt solution.

O Fator Wagner – RH Rápido®

Hand holding two Rapid RH Smart SensorsWagner Meters developed its RH testing products with easy calibration in mind. Its Rapid RH Smart Sensors, both the RH rápido L6 and the Rapid RH 5.0, are calibrated at the factory, so they’re ready to use right out of the box.

Rapid RH sensors come with a certificate of calibration, the calibration documentation ASTM F2170 calls for.

The Rapid RH L6 Smart Sensor makes it especially simple. Because it’s a single-use sensor, it never needs a calibration check, which makes it a good fit for contractors and flooring installers.

Manutenção da calibração para sensores reutilizáveis

Ao contrário do Sensor Inteligente Rapid RH L6, projetado para uso em um único local de teste, um sensor reutilizável pode ser usado em vários locais de teste. Após ser instalado em um local e a leitura ser realizada, ele pode ser removido e instalado em outro.

Para alguns inspetores de construção, inspetores de pisos, empresas de engenharia e alguns profissionais de controle de qualidade, um sistema reutilizável como o Rapid RH 5.0 pode fazer sentido.

However, to maintain ASTM F2170 compliance, the calibration of a reusable sensor must be checked within 30 days before it’s reused. Because of the extra time and attention that takes, a single-use system is usually the best choice for most contractors and flooring installers.

To keep those calibration checks simple and quick, Wagner Meters designed the Sensor Inteligente Rapid RH 5.0 reutilizável with that process in mind.

Each Rapid RH 5.0 reusable sensor comes with its own patented EasyCare CalCheck™ protective storage unit, which holds a 75% RH salt solution for checking calibration.

A câmara de armazenamento EasyCare CalCheck protege e armazena o Sensor Inteligente Reutilizável Rapid RH em condições ideais. Isso prolonga a vida útil de cada sensor e reduz significativamente o tempo necessário para verificar a calibração.

Download gratuito: Qual sensor de umidade relativa rápido é o ideal para você?
Download grátis – Qual sensor de umidade relativa rápido é ideal para você?

Each Rapid RH 5.0 sensor must be replaced annually with a newly certified sensor to maintain ASTM F2170 compliance.

The innovative design of the Rapid RH 5.0 makes it a great choice for anyone who prefers using a reusable RH sensor. And if you prefer a sensor that never needs a calibration check, the single-use Rapid RH L6 is the way to go.

Bottom line: reusable sensors cost more up front and take more time to use and maintain, but they can be used at as many test sites as needed for 12 months before any additional investment.

Mais importante do que o tipo de sensor que você escolher é a escolha que você faz sobre qual teste empregar.

Remember: RH testing is your best option for protecting the integrity of your work. When your work and reputation rest on the results of your moisture testing, a certified, accurate in-situ RH probe gives you the confidence you need.

Loja Rapid RH

Última atualização em 9 de outubro de 2026

2 Comentários

  1. Ryan diz:

    Oi,

    Estou tentando verificar a calibração dos nossos sensores Rapid RH 5.0. Estou usando o aplicativo DataMaster com o dispositivo Bluetooth e recebo uma mensagem de falha na calibração ao usar a configuração de NaCl. No entanto, entendo que isso não é necessariamente um grande problema e que o sensor e o dispositivo Bluetooth podem simplesmente precisar atingir o equilíbrio. Posso deixar o dispositivo Bluetooth conectado ao sensor e verificar novamente em algumas horas? Obrigado.

    • Jason Spangler diz:

      Ryan:

      Obrigado pela pergunta. A melhor maneira de fazer isso é por telefone. Ligue para mim quando tiver tempo: 800-634-9961 X235.

      Obrigado.

Deixa um comentário